Predictive maintenance on a vibration sensor
Problem: alert when a motor starts to look unhealthy. Uses: Khaos, NumPy and SciPy.Screen ECG recordings
Problem: rank recordings by how unusual they look so a clinician reviews the worst first. Uses: Khaos and wfdb.Alert on operating regime shifts
Problem: know when a plant moves into a different operating mode. Uses: Khaos and the standard library.Inputs and outputs for each model
These are real outputs of the v1 models, run through their exported ONNX files on held-out examples. The shapes listed are the exact ONNX inputs and outputs;batch and other named sizes are dynamic.
tele_sensor_vibration
A 3,200-sample vibration window, shape (1, 1, length), in. The model returns an embedding and an anomaly score: the reconstruction error (higher means more unusual). Raw sensor units are fine; each window is normalized inside the model.
Model inputs: x float32 [batch, 1, 3200]Model outputs:
vector float32 [batch, 128]; anomaly_score float32 [batch]
Input
tele_bio_ecg
A 2,048-sample ecg window, shape (1, 1, length), in. The model returns an embedding and an anomaly score: the probability that the window is abnormal. Raw sensor units are fine; each window is normalized inside the model.
Model inputs: x float32 [batch, 1, 2048]Model outputs:
vector float32 [batch, 128]; anomaly_score float32 [batch]
Input
tele_regime_shift
A multivariate window (8 channels x 512 samples; streams with fewer channels are zero-padded) in, one change probability per 8-sample patch out (64 values). Patches above the threshold are where the regime is predicted to change.
Model inputs: x float32 [batch, 8, 512]Model outputs:
change_logits float32 [batch, 64]
Input